Page 19 - Bürkert
P. 19

Pivot Operated 2/2-way Solenoid Valve in plastic






      0330  G 1/4”


            •  With separating diaphragm
            •  For aggressive media
            •   Also available for mounting on
                 manifolds (Type 0331)

            •   Standard with lockable manual override
                                                                      2 (A)

                                                                      1 (P)



         Direct-acting solenoid valve employing Bürkert’s unique pivoted armature.   Envelope Dimensions [mm] (see datasheet for details)
         A hermetic isolation is guaranteed against aggressive substances by the
         flexible diaphragm. Shown is the threaded version in precision moulded
         engineered polymer. The valve is also available in manifold mount as the
         Type 0331.

         Technical Data

          Temperature media     -30 °C to +80 °C (EPDM)          2508 cable plug Form A included
                                0 °C to +80 °C (FKM)
          Ambient temperature   +55 ºC, max.
          Voltage tolerance     ± 10%
          Duty cycle
            Intermittent operation  40% ED (30 min) with 8 W version
            Continuous operation  100% ED with 5 W version (on request)
          Body material         PP or PVDF
          Seal material         FKM or EPDM
                                NBR and FFKM on request
          Coil material         Epoxy (Class H)
          Power consumption     DC: 8 W, AC: 30 VA (inrush), 15 VA (hold)         Size     A     B      C
          Protection class      IP65 (with cable plug)
          Electrical connection  Cable plug acc. to DIN EN 175301-803,            G 1/4”  56     36    104
                                Form A (included)


                                 Response times
                           AC                  DC
           Orifice   Opening    Closing   Opening    Closing
            [mm]      [ms]      [ms]      [ms]     [ms]
             2-4      8-15      8-15     10-20     10-20
         Response times [ms]: Measured at valve outlet at 6 bar and +20 °C
         Opening: pressure build-up 0 to 90%, closing: pressure drop 100 to 10%

         Options
         •  2/2-way normally open, 3/2-way version
         •  Electrical position feedback
         •  Impulse coil
         •  Flange version
         •  Vacuum version
         •  CSA, ATEX and UR accreditation
         •  Alternative cable plug
         •  5 W coil






    18
   14   15   16   17   18   19   20   21   22   23   24