Electrical connections


               Open/Close version
                3 points Mode       On/Off Mode
                N           Ph      N              Ph                         FEEDBACK
                -           +        -             +                                                                 3003
                                                                         4   5   6   7   8  9

                                               OPEN   CLOSE
                        OPEN  CLOSE
                   TP/PE                TP/PE
                                                                        FC1     FC2
                   1  2                 1  2
                     3                   3



                                                                      Symbol  Designation
                                                                       FCO    Open limit switch
                                                                       FCF    Close limit switch
                                                                       FC1    Auxiliary 1 limit switch
                                                                       FC2    Auxiliary 2 limit switch



               Version with analogue signal input
                          N         Ph
                          -   TP/PE  +




                              1  2
                               3




                            1  2
                             3
                                           * Only for probe version            Feedback
                                            *
                                                                             4   5   6   7   8  9
                        1      2     3      4


                             10/30 W Card

                TP/PE                                       FCO     FCF     FC1     FC2
                           17 18
                           17 18                                ~
                                                               -  +
                                                                ~

                                                         A      B
                             P6 POSI
                                              A
                                              B
                           13  14  15  16                          The resolution of control operation is 1°
                                                                   The input resistance at control 0-10 V is 10 kW
                                                         MOTOR
                           +  -    -  +                    =       The input resistance at control 0-20 mA/4-20 mA is 100 W
                          Output   Input
                          signal   signal
                        0-20 mA / 4-20 mA / 0-10 V