Page 435 - Bürkert
P. 435
50 x DN 5 x DN
Installation
EN ISO 5167-1 specifies the straight inlet and outlet distances that must be complied with when installing fittings
in pipelines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the
40 x DN 5 x DN
flow are shown below, together with the associated minimum inlet and outlet distances. These ensure calm, problem-
free measurement conditions at the measurement point.
SE32 50 x DN 5 x DN 25 x DN 5 x DN
40 x DN 5 x DN 20 x DN 5 x DN
DN = pipe diameter Fluid direction -->
Pipe diameter
Control valve 2 x 90° elbow joint
extension
50 x DN 5 x DN 25 x DN 5 x DN 18 x DN 5 x DN
2 x 90° elbow joint 90° elbow joint Pipe diameter
3 dimensional or T-piece reduction
40 x DN 5 x DN 20 x DN 5 x DN 15 x DN 5 x DN
The device can be installed into either horizontal or vertical pipes.
25 x DN 5 x DN 18 x DN 5 x DN
Correct Incorrect
Incorrect
20 x DN 5 x DN 15 x DN 5 x DN
Incorrect Correct
Correct Correct Incorrect
18 x DN 5 x DN
Pressure/temperature Chart
15 x DN 5 x DN
P (bar) A
16 A: Application range for a complete device
15 Metal
14 (fitting + electronics)
13
12
11
10
9 PVDF
8 PVC + PP
7 PVDF (PN10)
6
5
4 PVC (PN10)
3
2
1 PP (PN10)
0 T °C
-30 -10 +10 +30 +50 +70 +90 +110